Blog Archive

Thursday, January 13, 2011

Battery Booster - 3






Battery Boosters connected to  Electric Buggy. It works on 48V DC. Batteries are rated at 150AH

A resort company had 6 Electric Buggies which has a carrying capacity of 9 people with luggage.

The batteries used were Trojan Trojan Battery Company - imported from US & quite expensive. They failed within less than an years time with bloated containers. Replacing batteries were becoming an expensive proposal, each set cost upwards of Rs: 70,000/-

With the Electric Buggy manufacturer reluctant to solve the problem blaming Battery maintenance, an investigation was started into the issue.

The problem was narrowed down  to the external 48V DC Charger supplied. It was over-charging the batteries with higher voltage (72v) leading to its premature failure.

Had it removed & replaced with custom-made external chargers having voltage & current control combined with Battery boosters attached to the batteries. This has enhanced the Battery life to more than 2 years & still going on.

After many complaints regarding Battery failure, the Electric Buggy manufacturer has been supplying new compact replacement external 48v chargers with voltage & current control.

The batteries from last year have been reproduced locally by Exide for almost half the cost.







Diesel Generator Fuel Saver - 3


The above picture shows Fuel saver connected to Volvo 380 KVA Generator. The Diesel fuel savings are in the tune of 6-8%. The gains are lesser because Volvo uses Electronically controlled direct injection technology. However the engine remains healthier because of lesser carbon accumulation.

Tuesday, January 11, 2011

Battery Booster - 2


Battery Booster connected to Volvo 380KVA Diesel Generator starter motor batteries

Diesel Generator Fuel Saver - 2


The Fuel Saver connected to 140KVA  Kirloskar Diesel Generator. Fuel efficiency has increased to 15%.

Tuesday, December 21, 2010

Diesel Generator Fuel Saver - 1


The above picture shows the Fuel Saver connected to 280 KVA Cummins Diesel Generator. The fuel efficiency has increased to 10 to 12% . The units generated per liter were compared on a daily basis prior to & post fitment.

Battery Booster - 1



The photo above shows Battery Boosters connected to 6 x 12v 200Ah Batteries. The UPS system is 5 KVA Line-interactive working on 72v DC.

The Batteries were purchased in 28/3/2007. The backup at 4KW load had dropped to 2 hrs after 2 years of usage. After connecting the Battery Pulsers, over 2 months the backup has increased to 4 hrs .